Test on the brake with 45°C oil temperature
- Empty test
- Loaded test V 360 - 380 - 400 - 415 in power and torque
- Cyclical test of plants tor residential use: rated tension + - 5% 20” on 80”
off observation of the behaviour of technical protector.
- Cyclical test of plants tor continuous use: rated tension + - 5% 13” on 32”
off. Charge 1.1 rated power.
- Cyclical test of removal: rated tension - 5% 5” on 10” off nr. 20 consecutive
insertions.
- Specifics concerning the motor shaft torque: the motor must move a
maximum rated torque of 1.87
- High pressure valve setting: rated torque of 1.7 maintained tor 20” with
rated tension of 0.95
- Cold motor starting linked to cog wheel: starting torque must result - 0.4
rated torque.
- Long run: rated power of 1.3 for 60” with a rated tension of 0.9.
Relief intervention of the thermal protector.